If you have a metering valve adjustment device. Use the suction control valve adjusting device (signal generator) on the pump to adjust the driving current of the suction control valve to see the change of rail pressure.The diesel suction control valve can be removed from the pump, and the driving current of the valve can be adjusted by the suction control valve common rail diesel adjusting device (signal generator) to see the movement of the spool.